Case 1 - The indicator light turns on "only sometimes": may be due to an unstable electrical connection.
Remedy: Check all the points of the circuit and tighten the connections are unstable or uncertain.
Case 2 - The indicator light "does not turn on absolutely": still may be due to an unstable connection or a broken wire.
Remedy: as above
Case 3 - The indicator light "does not turn on absolutely" can also be due to a broken lamp.
Remedy: Check and, if necessary, replace the lamp.
Case 4 - The electromagnetic sensor is unregulated and not from the consent of the Micro dosing power (check that the arrow sensor is aligned with the adjustment line on the sticker on the front)
The adjustment of the electromagnetic sensor is done as follows:
- Bring 2 mm Allen key (supplied)
- Loosen the small peak screw placed on the black body of the sensor,
- Slide the sensor until the arrow lines up with the line sensor adjustment.
- Tighten back the small peak screw with the Allen key.